Sl No. | District
As per Census (2011)
|
Block
As per Census (2011)
|
Division
Working Divisions
|
Scheme
Schemes for which Work Order has been issued as per PHED-MIS
|
Scheme Category
Category of Scheme as per PHED-MIS
|
Work Name
Name of the Work as per the Issued Work Order
|
Name of AE entrusted | Name of JE entrusted | System Order No.
System Order Number
|
WO Number
Manual No. Provided by the Divisions as per PHED-MIS
|
WO Date
Date of Issuance of Work Order
|
Days of Completion
Target Days for Work Completion as per PHED-MIS
|
Agency Name
Agency Appointed Against this Work Order as per PHED-MIS
|
Work Value
Value of Work as mentioned in the Work Order as per PHED-MIS
|
Payment
Amount of Payment made for this Work Order as per PHED-MIS
|
Payment %
Percentage of Payment made for this Work Order as per PHED-MIS
|
Physical Progress %
Achievement of Physical Progress of the work under this Work Order as per PHED-MIS
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
14 | 812.6 | 322.11 | 39.64 | ||||||||||||||
1 | HOWRAH | Bagnan - II | Howrah Division | Matinala Piped Water Supply Scheme , SM/15285 | New | Preparation of DPR for Augmentation of Matinala (Mellock Zone-I) PWSS, Bagnan-II Block under Uluberia Sub-Division of Howrah Division PHE Dte. | AE/Ulu | ORD/000225/2022-2023 | 317/AE/USD | 16/08/2022 | 45 | MS SOBHA AND CO | 3.61 | 3.51 | 97.23 | 100 | |
2 | HOWRAH | Bagnan - II | Howrah Division | Matinala Piped Water Supply Scheme , SM/15285 | New | Sinking of 5 (Five) No. 250 X 150 mm Dia and 230 m deep tubewell Drilling by Direct Rotary method with UPVC Pipes all complete at Harop PWSS Zone -I (1 no) & Zone-II (2 nos) & Matinala PWSS (2 nos) of Bagnan-I Block of Uluberia Sub-Division under Howrah Division, P.H.E. Dte. | AE/Ulu | JE-USD,je/blk/bagn1,JE/USD | ORD/000249/2023-2024 | 3533/HD | 04/10/2023 | 60 | AQUATECH ENGINEERS | 64.95 | 7.51 | 11.56 | 40 |
3 | HOWRAH | Bagnan - II | Howrah Division | Matinala Piped Water Supply Scheme , SM/15285 | New | Balance Laying of distribution pipeline Matinala PWSS of Bagnan-II Block under Uluberia Sub-Division, under Howrah Division P.H.E. Dte. (Mouza-Mellock) | AE/Ulu | JE/USD | ORD/000585/2023-2024 | 3104/AE/USD | 29/02/2024 | 45 | BISWAJIT BAG | 13.00 | 8.03 | 61.77 | 100 |
4 | HOWRAH | Bagnan - II | Howrah Division | Matinala Piped Water Supply Scheme , SM/15285 | New | Balance Laying of distribution pipeline Matinala PWSS of Bagnan-II Block under Uluberia Sub-Division, under Howrah Division P.H.E. Dte. (Mouza-Matinala) | AE/Ulu | JE/USD | ORD/000687/2023-2024 | 3242/AE/USD | 12/03/2024 | 45 | SUNIRMAN ENTERPRISE | 11.92 | 5.96 | 50 | 100 |
5 | HOWRAH | Bagnan - II | Howrah Division | Matinala Piped Water Supply Scheme , SM/15285 | New | Work Order for Laying Distribution System(HDPE & DI) & providing Functional Household Tap Connection (FHTC) of MATINALA PWSS OF BAGNAN-II BLOCK UNDER THE ULUBERIA SUB-DIVISION UNDER HOWRAH DIVISION, P.H.E. DTE. (PART-C) | AE/Ulu | JE/USD | ORD/000763/2022-2023 | 705/HD | 22/02/2023 | 120 | SUNIRMAN ENTERPRISE | 66.28 | 23.63 | 35.65 | 40 |
6 | HOWRAH | Bagnan - II | Howrah Division | Matinala Piped Water Supply Scheme , SM/15285 | New | Work Order for Laying Distribution System(HDPE & DI) & providing Functional Household Tap Connection (FHTC) MATINALA PWSS OF BAGNAN-II BLOCK UNDER THE ULUBERIA SUB-DIVISION UNDER HOWRAH DIVISION, P.H.E. DTE. (PART-D) | AE/Ulu | JE/USD | ORD/000764/2022-2023 | 706/HD | 22/02/2023 | 60 | USHA CONCERN | 73.23 | 36.28 | 49.54 | 30 |
7 | HOWRAH | Bagnan - II | Howrah Division | Matinala Piped Water Supply Scheme , SM/15285 | New | Work Order for Laying Distribution System(HDPE & DI) & providing Functional Household Tap Connection (FHTC) & Interconnection between tube well & Construction of 450 cu.m. capacity 20 mtr staging height RCC Over Head Reservoir including Pipe connection & soil investigation for MATINALA PWSS OF BAGNAN-II BLOCK UNDER THE ULUBERIA SUB-DIVISION UNDER HOWRAH DIVISION, P.H.E. DTE. (PART-B) | AE/Ulu | JE/USD | ORD/000840/2022-2023 | 1141/HD | 21/03/2023 | 120 | ADITYA HAZRA | 218.71 | 125.93 | 57.58 | 80 |
8 | HOWRAH | Bagnan - II | Howrah Division | Matinala Piped Water Supply Scheme , SM/15285 | New | Work Order for Laying Distribution System(HDPE & DI) & providing Functional Household Tap Connection (FHTC) at Matinala PWSS of Bagnan-II Block under Uluberia Sub-Division, under Howrah Division P.H.E. Dte. (Part-A) | AE/Ulu | JE/USD | ORD/000882/2022-2023 | 1436/HD | 29/03/2023 | 120 | BISWAJIT BAG | 163.00 | 111.26 | 68.26 | 40 |
9 | HOWRAH | Bagnan - II | Howrah Division | Matinala Piped Water Supply Scheme , SM/15285 | New | Material Requisition To Resource Division | RTOR000024/2023-2024 | 1754/HD | 26/04/2023 | Resource Division | 27.35 | 0.00 | 0 | 0 | |||
10 | HOWRAH | Bagnan - II | Howrah Division | Matinala Piped Water Supply Scheme , SM/15285 | New | Material Requisition To Resource Division | RTOR000048/2023-2024 | 2979/HD | 17/08/2023 | Resource Division | 26.58 | 0.00 | 0 | 0 | |||
11 | HOWRAH | Bagnan - II | Howrah Division | Matinala Piped Water Supply Scheme , SM/15285 | New | Material Requisition To Resource Division | RTOR000096/2023-2024 | 170/HD | 15/01/2024 | Resource Division | 10.29 | 0.00 | 0 | 0 | |||
12 | HOWRAH | Bagnan - II | Electrical | Matinala Piped Water Supply Scheme , SM/15285 | New | Quotation for new service connection for Matinala Water Supply Scheme, PH NO- II, in the district Howrah under Electrical Division, PHE Dte. ( SM/15285), Reference Id- 106538620 , Application no- 1007634961 | BILL/00087/2024-2025 | 40 | 09/04/2024 | WBSEDCL | 4.07 | 0.00 | 0 | null | |||
13 | HOWRAH | Bagnan - II | Electrical | Matinala Piped Water Supply Scheme , SM/15285 | New | Adhoc payment to WBSEDCL against service connnection | BILL/01127/2023-2024 | null | 28/06/2023 | WBSEDCL | 109.23 | 0.00 | 0 | 0 | |||
14 | HOWRAH | Bagnan - II | Electrical | Matinala Piped Water Supply Scheme , SM/15285 | New | Supply, delivery & installation of submersible pumping machinery and other electrical/ mechanical equipments etc. including allied works for Matinala water supply scheme, T.W. No.- I & II, Block: Bagnan-II, District- Howrah under Electrical Division, PHE Dte. | Assistant Engineer Howrah mechanical Sub Division | Junior Engineer2 | ORD/000261/2022-2023 | 928/ED | 22/02/2023 | 90 | R.M.D TRADING. | 20.38 | 0.00 | 0 | 0 |
Total | 812.60 | 322.11 | 39.64 |